‘Structures’ Category

November 19 2016

ALCAPARROSA VIADUCT

Client Sacyr Chile S.A. Scope Structural design based on dynamic analysis and Seismic Isolation according to AAHSTO 2010 standard. Lenght 220 m Height 56 m Description 5 continuous Spans with lengths between 40...

November 18 2016

FISCAL BRIDGE

Client Sacyr Chile S.A. Scope Structural design based on dynamic analysis and Seismic Isolation according to AAHSTO 2010 standard. Lenght 180 m Height 13.5 m Description 5 spans of 36 m long each. Deck...

November 18 2016

JUAN SOLDADO BRIDGE

Client Sacyr Chile S.A. Scope Structural design based on dynamic analysis and Seismic Isolation according to AAHSTO 2010 standard. Length  160 m Heigth 35.5 m Description 4 spans of 40 m long each....

November 17 2016

GREAT TELESCOPE LSST (AURA)

Client Besalco Construcciones Scope Review and optimization of next areas: Geomechanic – Arquitecture – Structure, Great Telescope of Sinoptical Research (LSST)”. Geomechanical topic Optimization such as: foundation support, rock anchorage, excavations slope and...

November 16 2016

PIÑÓN BLANCO WIND FARM – CHILE

Client Acciona Energy Chile Scope Asessment of Deterministic seismic hazard and soil dynamic amplification analysis. Power 46 Wind turbines of 3 MW power. Description 87.5 m height with steel tower. Location Angol, Chile. Year 2016.

November 16 2016

RENAICO WIND FARM – CHILE

Client Acciona Energy Chile Scope Asessment of Deterministic seismic hazard and soil dynamic amplification analysis (Preliminary study). Power 61 Wind turbines of 3 MW power. Description 120 m height and precast post tensioned concrete...

November 16 2016

CANELA II WIND FARM – CHILE

Client Acciona Windpower Spain Scope Structuctural design of shallow and deep foundations according to NCh2369-2003 local code. Power 40 Wind turbines of 1.5 MW power.  140.6 GWh of annual Production. Description 82 m...

March 20 2018

EL ARREBOL WIND FARM – CHILE

Client Senvion Chile Scope Consulting on Earthquake Engineerign for design of wind turbines according to NCh2369-2003 local code. Power 3 Wind turbines of 110 m high supported by steel tower. Description Seismic Guidelines for seismic design...

November 15 2016

PUNTA PALMERAS WIND FARM – CHILE

Client Acciona Windpower Spain Scope Structural design of round spread foundation according to NCh2369-2003 local code. Power 15 Wind turbines of 3 MW power.  124 GWh of annual production Description 92 m height with steel...

September 11 2016

HUASCO BRIDGE

Client Sacyr Chile S.A. Scope Structural review and seismic certification. Segmental postensioned box deck (in-situ). Lengh 200 m (116 m central span ). Height 30 m Location Vallenar – Caldera Highway, Copiapo, Chile Year 2011