‘Structures’ Category
ALCAPARROSA VIADUCT

Client Sacyr Chile S.A. Scope Structural design based on dynamic analysis and Seismic Isolation according to AAHSTO 2010 standard. Lenght 220 m Height 56 m Description 5 continuous Spans with lengths between 40...
FISCAL BRIDGE

Client Sacyr Chile S.A. Scope Structural design based on dynamic analysis and Seismic Isolation according to AAHSTO 2010 standard. Lenght 180 m Height 13.5 m Description 5 spans of 36 m long each. Deck...
JUAN SOLDADO BRIDGE

Client Sacyr Chile S.A. Scope Structural design based on dynamic analysis and Seismic Isolation according to AAHSTO 2010 standard. Length 160 m Heigth 35.5 m Description 4 spans of 40 m long each....
GREAT TELESCOPE LSST (AURA)

Client Besalco Construcciones Scope Review and optimization of next areas: Geomechanic – Arquitecture – Structure, Great Telescope of Sinoptical Research (LSST)”. Geomechanical topic Optimization such as: foundation support, rock anchorage, excavations slope and...
PIÑÓN BLANCO WIND FARM – CHILE

Client Acciona Energy Chile Scope Asessment of Deterministic seismic hazard and soil dynamic amplification analysis. Power 46 Wind turbines of 3 MW power. Description 87.5 m height with steel tower. Location Angol, Chile. Year 2016.
RENAICO WIND FARM – CHILE

Client Acciona Energy Chile Scope Asessment of Deterministic seismic hazard and soil dynamic amplification analysis (Preliminary study). Power 61 Wind turbines of 3 MW power. Description 120 m height and precast post tensioned concrete...
CANELA II WIND FARM – CHILE

Client Acciona Windpower Spain Scope Structuctural design of shallow and deep foundations according to NCh2369-2003 local code. Power 40 Wind turbines of 1.5 MW power. 140.6 GWh of annual Production. Description 82 m...
EL ARREBOL WIND FARM – CHILE

Client Senvion Chile Scope Consulting on Earthquake Engineerign for design of wind turbines according to NCh2369-2003 local code. Power 3 Wind turbines of 110 m high supported by steel tower. Description Seismic Guidelines for seismic design...
PUNTA PALMERAS WIND FARM – CHILE

Client Acciona Windpower Spain Scope Structural design of round spread foundation according to NCh2369-2003 local code. Power 15 Wind turbines of 3 MW power. 124 GWh of annual production Description 92 m height with steel...
HUASCO BRIDGE

Client Sacyr Chile S.A. Scope Structural review and seismic certification. Segmental postensioned box deck (in-situ). Lengh 200 m (116 m central span ). Height 30 m Location Vallenar – Caldera Highway, Copiapo, Chile Year 2011